Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 98
Filter
1.
Dental press j. orthod. (Impr.) ; 28(4): e2322220, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1514056

ABSTRACT

ABSTRACT Objective: The aim of this randomized clinical trial was to evaluate and compare, during the first week of rapid maxillary expansion (RME), the impact caused by two types of appliances: Hyrax and Hybrid Hyrax. Methods: Forty-two patients who met the eligibility criteria (aged 11-14 years, with transverse maxillary deficiency, posterior crossbite, and presence of maxillary first premolars and first permanent molars) were selected and randomly divided into two groups: TBB GROUP (tooth-bone-borne expander), treated with Hybrid Hyrax (12 females and 9 males, mean age 13.3 ± 1.3 years), and TB GROUP (tooth-borne expander), treated with Hyrax (5 females and 16 males, mean age 13.3 ± 1.4 years). Pain and discomfort were assessed in two times: after the first day of activation (T1) and four days after, by means of the numerical rate scale and the instrument MFIQ (Mandibular Functional Impairment Questionnaire). Descriptive statistics and the Mann-Whitney test were used for comparison between groups and between sexes. A 5% significance level was adopted. Results: Both appliances had a negative impact, generating pain and discomfort, and reducing functional capacity. However, the scores obtained were of low intensity and no significant differences were observed between the groups. Considering sexes, there were statistically significant differences, with the female sex presenting higher scores for pain and functional limitation. Conclusions: Despite causing impact in pain and increase in the functional limitation, these changes were of low intensity, with no statistical difference between the groups. Females were more sensitive to the impact caused by the RME.


RESUMO Objetivo: O objetivo deste ensaio clínico randomizado foi avaliar e comparar, durante a primeira semana de expansão rápida da maxila (ERM), o impacto causado por dois tipos de aparelhos: Hyrax e Hyrax Híbrido. Métodos: Quarenta e dois pacientes que atendiam aos critérios de seleção (idade de 11 a 14 anos, com deficiência transversal da maxila, mordida cruzada posterior e presença de primeiros pré-molares e primeiros molares permanentes superiores) foram selecionados e divididos aleatoriamente em dois grupos: Grupo DOS (expansor dento-osseossuportado), tratado com Hyrax Híbrido (12 mulheres e 9 homens, idade média 13,3 ± 1,3 anos), e Grupo DS (expansor dentossuportado), tratado com Hyrax (5 mulheres e 16 homens, idade média de 13,3 ± 1,4 anos). A dor e o desconforto foram avaliados em dois momentos: após o primeiro dia de ativação (T1) e após quatro dias, por meio da escala de frequência numérica e do instrumento MFIQ (Questionário de Limitação Funcional Mandibular). A estatística descritiva e o teste de Mann-Whitney foram utilizados para comparação entre os grupos e entre os sexos. Adotou-se nível de significância de 5%. Resultados: Ambos os aparelhos tiveram impacto negativo, gerando dor e desconforto e reduzindo a capacidade funcional. No entanto, os escores obtidos foram de baixa intensidade e não foram observadas diferenças significativas entre os grupos. Considerando os sexos, houve diferenças estatisticamente significativas, com o sexo feminino apresentando maiores escores para dor e limitação funcional. Conclusões: Apesar de causar impacto na dor e aumento na limitação funcional, essas alterações foram de baixa intensidade, sem diferença estatística entre os grupos. As mulheres foram mais sensíveis ao impacto causado pela ERM.

2.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1411432

ABSTRACT

Objective: to analyze the stress distribution in a 3D model that simulates second molar mesialization using two different types of mini-implants. Material and Methods: a mandible bone model was obtained by recomposing a computed tomography performed by a software program. The cortical and trabecular bone, a lower second molar, periodontal ligament, orthodontic tube, resin cement and the mini-implants were designed and modeled using the Rhinoceros 4.0 software program. The characteristics of self-drilling orthodontic mini-implants were: one with 7 mm length, 1 mm transmucosal neck section and 1.6 mm diameter and another with 5 mm length and 1.5 mm diameter. A total of 235.161 and 224.505 elements were used for the mesh. These models were inserted into the bone block and then subjected to loads of 200 cN (centinewton). The results were calculated and analyzed by the Ansys 17.0 software program for qualitative verification through displacement and maximum principal stress maps. Results: it was possible to observe that the periodontal ligament presented low displacement and stress values. However, the physiological values presented are among those capable to provide orthodontic movement, with compression and tensile area visualization staggered between 0.1 and -0.1 MPa (megapascal). Conclusion: within the limitations of the study, the mini-implants tested showed similar results where the load on the tooth allowed dental displacement (molar mesialization), with a tendency to rotate it, theoretically allowing the second molar to take the location of the first molar. (AU)


Objetivo: analisar a distribuição de tensões em um modelo 3D que simula a mesialização do segundo molar usando dois tipos diferentes de mini-implantes. Material e Métodos: um modelo de osso mandibular foi obtido por recomposição de uma tomografia computadorizada realizada por um software. O osso cortical e trabecular, um segundo molar inferior, ligamento periodontal, tubo ortodôntico, cimento resinoso e os mini-implantes foram projetados e modelados no software Rhinoceros 4.0. As características dos mini-implantes ortodônticos auto perfurantes foram: um com 7 mm de comprimento, 1 mm de secção transmucosa e 1,6 mm de diâmetro e outro com 5 mm de comprimento e 1,5 mm de diâmetro. Para a malha, foram utilizados 235.161 e 224.505 elementos. Esses modelos foram inseridos no bloco ósseo e então submetidos a cargas de 200 cN (centinewton). Os resultados foram calculados e analisados pelo software Ansys 17.0 para verificação qualitativa por meio de mapas de deslocamento e tensões máximas principais. Resultados: foi possível observar que o ligamento periodontal apresentou baixos valores de deslocamento e tensões. Porém, os valores fisiológicos apresentados são capazes de proporcionar movimentação ortodôntica, com visualização da área de compressão e tração escalonada entre 0,1 e -0,1 MPa (megapascal). Conclusão: dentro das limitações do estudo, os mini-implantes testados apresentaram resultados semelhantes onde a carga sobre o dente permitiu o deslocamento dentário (mesialização do molar), com tendência a girá-lo, permitindo teoricamente que o segundo molar ocupe do lugar do primeiro molar (AU)


Subject(s)
Tooth Avulsion , Dental Implants , Finite Element Analysis , Orthodontic Anchorage Procedures , Orthodontic Appliances, Fixed
3.
Dental press j. orthod. (Impr.) ; 27(5): e222190, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1404496

ABSTRACT

ABSTRACT Objective: To investigate the influence of dynamic visualization of cone beam computed tomography (CBCT) scans on orthodontist's assessment of positioning status and prognosis of interradicular mini-implants (MI). Methods: Three MI positions were virtually simulated in thirty CBCT volumes: (1) MI 1 mm from the lamina dura (LD), (2) MI touching the LD and (3) MI overlapping the LD. Each position was exposed to orthodontists (n = 35) as panoramic reconstruction, sagittal reconstruction and a sequence of axial slices. Each orthodontist evaluated the MI position (relationship with the LD) and scored the prognosis using a four-point scale (the higher the score, the better the prognosis). Kappa, Friedman and Nemenyi statistics were used. Results: Statistically significant associations were detected between the prognosis scores and the type of image visualized (p<0.05). The dynamic visualization of the CBCT volume (axial slices) was associated with higher scores for prognosis and more reliable evaluation of MI positioning. Inconsistent outcomes were more frequently associated with panoramic and sagittal reconstructions. Conclusion: The dynamic visualization of axial slices allowed orthodontists to perform better assessment of MI position and considerably affected prognosis judgment.


RESUMO Objetivo: Analisar se a avaliação dinâmica de volumes de tomografia computadorizada de feixe cônico (TCFC) influencia a percepção de ortodontistas quanto à determinação da posição e do prognóstico de mini-implantes (MIs) inter-radiculares. Material e Métodos: Foram selecionados 30 volumes de TCFC, nos quais foram simuladas três formas de instalação de MIs: 1) MI a 1 mm de distância da lâmina dura (LD); 2) MI tocando a LD; e 3) MI sobreposto à LD. As imagens foram examinadas por 35 ortodontistas na forma de reconstruções panorâmicas, reconstruções sagitais e uma sequência de reconstruções axiais. Os examinadores avaliaram a relação entre o MI e a LD, e indicaram o prognóstico dos MIs instalados, usando uma escala de 4 pontos (quanto maior o escore, mais favorável o prognóstico). Os dados foram submetidos à análise estatística, por meio dos testes de Kappa, Friedman e Nemenyi. Resultados: Houve associação significativa entre o prognóstico, os tipos de imagem e as três formas de inserção dos MIs (p<0,05). A visualização dinâmica dos volumes de TCFC (reconstruções axiais) foi associada a maiores escores para o prognóstico e a avaliações mais confiáveis da posição dos MIs. Escores mais inconsistentes e discordantes foram mais associados às reconstruções panorâmicas e sagitais. Conclusão: A análise do volume tomográfico em reconstruções axiais pode melhorar a avaliação do ortodontista quanto à posição dos MIs inter-radiculares, apresentando impacto significativo na determinação do prognóstico do caso.

4.
Dental press j. orthod. (Impr.) ; 27(6): e22bbo6, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1430265

ABSTRACT

ABSTRACT Introduction: Miniscrew or microimplant-assisted rapid palatal expansion (MARPE) devices are used to achieve a skeletal expansion of the palate and to increase the arch perimeter. Objective: To describe the treatment of a 23-year-old woman with an Angle Class II, division 1 malocclusion with constricted maxillary and mandibular arches. Case report: The patient's main complaint was mandibular anterior crowding. The treatment plan included expansion of the mandibular arch concurrent with maxillary expansion, using a MARPE appliance in combination with a full-fixed appliance to align and level the crowded mandibular teeth, along with miniscrews as anchorage for the maxillary teeth and for distalization of the molars and premolars. A successful non-extraction orthodontic treatment was accomplished after 28 months, and the occlusion and teeth alignment, as well as facial goals, were resolved in a clinically satisfactory manner. Conclusion: The treatment objectives were met, and the outcome of the expansion of the maxillary arch with a MARPE appliance as an adjunct to a fixed appliance was considered a success. An esthetic, functional, and stable result after a 1-year follow-up was achieved and was satisfactory to the patient.


RESUMO Introdução: Os aparelhos para expansão rápida da maxila (ERM) apoiada em mini-imlantes (MI) (MARPE) são usados para obter uma expansão esquelética do palato e aumentar o perímetro da arcada dentária superior. Objetivo: Este relato de caso descreve o tratamento de uma paciente do sexo feminino de 23 anos de idade, com má oclusão Classe II de Angle, divisão 1, com constrição das arcadas superior e inferior. Relato de caso: A queixa principal da paciente era o apinhamento anteroinferior. O plano de tratamento incluiu a expansão maxilar usando o aparelho MARPE, em combinação com aparelho fixo para a expansão da arcada inferior, concomitante ao alinhamento e nivelamento. Utilizou-se MI como ancoragem para a distalização dos molares e pré-molares superiores. O tratamento ortodôntico sem extrações foi realizado em 28 meses, e a oclusão e o alinhamento dos dentes, assim como os resultados faciais obtidos, foram clinicamente satisfatórios. Conclusão: Os objetivos do tratamento foram alcançados, e o resultado da ERM com aparelho MARPE junto ao aparelho fixo foi considerado um sucesso. Observou-se resultados estéticos e funcionais estáveis após um ano de acompanhamento, satisfatórios para a paciente.

5.
Dental press j. orthod. (Impr.) ; 26(1): e211965, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154060

ABSTRACT

ABSTRACT Objective: The aim of this study was to evaluate the thickness of the zygomatic-maxillary cortical bone using computed tomography in different skeletal patterns. Methods: A total of 54 patients of both sexes, divided into three groups according to the vertical skeletal pattern, were evaluated for cortical bone thickness of the anterior slope of the zygomatic process of the maxilla, using cone beam computed tomography. Measurements were made at 2mm, 4mm, 6mm, 8mm and 10mm above from first molar mesial root apex. Vertical skeletal pattern was determined by Frankfurt mandibular angle (FMA). Results: The hyperdivergent pattern had the lowest cortical thickness value, nevertheless, no patient in the hyperdivergent group presented cortical thickness exceeding 2mm, and no patient in the hypodivergent group presented cortical thickness less than 1mm. However, the correlation between cortical thickness and mandibular plane angle was weak and not significant. Conclusion: Although higher prevalence of thick cortical was observed in the hypodivergent patients, and thin cortical groups in the hyperdivergent group, the vertical skeletal pattern could not be used as determinant of the zygomatic-maxillary cortical thickness.


RESUMO Objetivo: O objetivo do presente estudo foi avaliar a espessura da cortical óssea zigomático-maxilar por meio de tomografia computadorizada em diferentes padrões esqueléticos. Métodos: Um total de 54 pacientes de ambos os sexos, divididos em três grupos, de acordo com o padrão esquelético vertical, foi avaliado quanto à espessura da cortical óssea na vertente anterior do processo zigomático da maxila, por meio de tomografia computadorizada de feixe cônico. As medidas foram feitas a 2mm, 4mm, 6mm, 8mm e 10mm acima do ápice da raiz mesial do primeiro molar. O padrão esquelético vertical foi determinado pelo Ângulo do Plano Mandibular (FMA). Resultados: O padrão hiperdivergente apresentou o menor valor de espessura de cortical. No entanto, nenhum paciente do grupo hiperdivergente apresentou espessura cortical superior a 2mm e nenhum paciente do grupo hipodivergente apresentou espessura cortical inferior a 1mm. No entanto, a correlação entre a espessura da cortical e o ângulo do plano mandibular foi fraca e não significativa. Conclusão: Embora tenha havido uma maior prevalência de cortical espessa no grupo hipodivergente e cortical fina no grupo hiperdivergente, o padrão esquelético vertical não pode ser utilizado como determinante da espessura cortical zigomático-maxilar.


Subject(s)
Humans , Male , Female , Cephalometry , Mandible , Maxilla , Cone-Beam Computed Tomography , Cortical Bone/diagnostic imaging , Mandible/diagnostic imaging , Maxilla/diagnostic imaging
6.
Dental press j. orthod. (Impr.) ; 26(1): e21bbo1, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154064

ABSTRACT

ABSTRACT Introduction: Orthodontic treatment in patients with traumatized teeth is a condition that needs good planning in order to achieve satisfactory results. Objective: To discuss approaches to orthodontic treatment of malocclusions associated with trauma followed by avulsion of anterior teeth, reimplanted after a short period of time. Case report: The treatment started with the distalization of upper posterior teeth, with the aid of mini-implants and sliding jigs, followed by the inclusion of anterior teeth in the arch, followed by intrusion of these teeth. Results: With the treatment, improved mobility of the anterior teeth was achieved, with better insertion into bone tissue. The most important factor for satisfactory treatment and a good prognosis for avulsion is the time the tooth remains outside the socket. Orthodontic treatment in patients with traumatized teeth is not contraindicated; however, clinical and radiographic aspects must be considered. Conclusion: Among the feasible orthodontic treatment options, the conservative approach can be a very favorable treatment alternative.


RESUMO Introdução: O tratamento ortodôntico em pacientes com dentes traumatizados é uma condição que necessita de um bom planejamento, a fim de se conseguir resultados satisfatórios. Objetivo: Discutir as abordagens de tratamento ortodôntico de más oclusões associadas ao trauma seguido de avulsão de dentes anteriores, reimplantados após curto espaço de tempo. Relato do Caso: O tratamento realizado iniciou-se com a distalização dos dentes posteriores superiores, com auxílio de mini-implantes e sliding jigs, seguida da inclusão dos dentes anteriores na arcada e intrusão desses dentes. Resultados: Com a realização do tratamento, conseguiu-se melhoria na mobilidade dos dentes anteriores, com inserção mais favorável no tecido ósseo. O fator mais importante para o tratamento satisfatório e um bom prognóstico da avulsão é o tempo em que o dente permanece fora do alvéolo. O tratamento ortodôntico em pacientes com dentes traumatizados não é contraindicado; porém, aspectos clínicos e radiográficos devem ser considerados. Conclusão: Entre as opções de tratamento ortodôntico factíveis, a abordagem conservadora pode ser uma opção de tratamento bastante favorável.


Subject(s)
Humans , Adult , Tooth Avulsion , Conservative Treatment , Malocclusion , Tooth Avulsion/complications , Tooth Avulsion/therapy , Tooth Avulsion/diagnostic imaging , Tooth Movement Techniques , Follow-Up Studies , Incisor/diagnostic imaging
7.
Dental press j. orthod. (Impr.) ; 26(1): e211967, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154066

ABSTRACT

ABSTRACT Objective: Assess the influence of mono- and bicortical anchorage and diameter of mini-implants (MIs) on the primary stability of these devices. Methods: 60 self-drilling MIs were distributed in six groups according to diameter (1.5mm, 1.8mm or 2.0mm) and type of anchorage (monocortical and bicortical) in bovine rib. The primary stability was evaluated by insertion torque, micromobility and pull-out strength tests. ANOVA and/or Tukey analysis were used to conduct intergroup comparisons (p< 0.05). Non-parametric statistics (Kruskal-Wallis and Mann-Whitney) were performed when normality was not found (p< 0.05). Results: MIs with larger diameters and bicortical anchorage showed greater primary stability regarding insertion torque (p< 0.05) and micromobility (p< 0.05). Only MI diameter had an effect on the pull-out strength test. Larger diameter MIs presented better retention in pull-out strength tests (p< 0.001), regardless of mono- or bicortical anchorage. Conclusions: MI primary stability is dependent on its diameter and type of anchorage. Bicortical anchorage showed greater stability when compared with monocortical anchorage, independently of other variables.


RESUMO Objetivo: Avaliar a influência da ancoragem mono e bicortical e do diâmetro dos mini-implantes (MIs) na estabilidade primária desses dispositivos. Métodos: 60 MIs autoperfurantes foram distribuídos em seis grupos, de acordo com o diâmetro (1,5 mm, 1,8 mm ou 2,0 mm) e tipo de ancoragem (monocortical e bicortical), e inseridos em costela bovina. A estabilidade primária foi avaliada pelos testes de torque de inserção, micromobilidade e resistência à tração. ANOVA e/ou análise de Tukey foram usadas para realizar comparações intergrupos (p< 0,05). Estatística não paramétrica (Kruskal-Wallis e Mann-Whitney) foi realizada quando a normalidade não foi encontrada (p< 0,05). Resultados: MIs com diâmetros maiores e ancorados bicorticalmente apresentaram maior estabilidade primária em relação ao torque de inserção (p< 0,05) e micromobilidade (p< 0,05). Apenas o diâmetro do MI influenciou os resultados do teste de resistência à tração. MIs de maior diâmetro apresentaram melhor retenção nos testes de resistência à tração (p< 0,001), independentemente da ancoragem mono ou bicortical. Conclusões: a estabilidade primária do MI é dependente de seu diâmetro e tipo de ancoragem. A ancoragem bicortical apresentou maior estabilidade quando comparada à ancoragem monocortical, independentemente das demais variáveis.


Subject(s)
Humans , Cattle , Dental Implants , Orthodontic Anchorage Procedures , Palate , Palatal Expansion Technique , Torque
8.
Dental press j. orthod. (Impr.) ; 25(6): 59-68, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1154058

ABSTRACT

ABSTRACT Objectives: Assess the stability of three different mini-implants, based on thread shape factor (TSF), and evaluate stresses at the mini-implant site and surrounding cortical bone on application of retraction force, at two different insertion angles. Methods: Mini-implants of three different diameters (M1 - Orthoimplant, 1.8mm), (M2 - Tomas, 1.6mm) and (M3 - Vector TAS, 1.4mm) and length of 8mm were used. Using scanning electronic microscopy, the mean thread depth, pitch and relationship between the two (TSF) were calculated. The mini-implants were loaded into a synthetic bone block and the pull-out strength was tested. One way ANOVA and Tukey post-hoc tests were used to compare the pull-out strength of mini-implants. P values < 0.05 were considered statistically significant. Finite element models (FEM) were constructed with insertion angulation at 90° and 60°, with retraction force of 150 g. The results were analyzed using ANSYS software. Results: Statistically significant difference was found among all the three mini-implants for thread depth and pitch (< 0.001). Statistically significant higher pull-out force value was seen for Orthoimplant. The stress distribution level in mini-implant and surrounding bone was observed to be smaller for Orthoimplant. Conclusion: Orthoimplant mini-implants have more favorable geometric characteristics among the three types, and less stress with 90°angulation.


RESUMO Objetivos: Avaliar a estabilidade de três diferentes tipos de mini-implantes, com base no fator formato da rosca (thread shape factor, TSF), e avaliar a tensão no local de inserção e no osso cortical ao redor dos mini-implantes inseridos com dois ângulos diferentes, durante a aplicação de força para retração. Métodos: Foram usados três diferentes diâmetros de mini-implantes, sendo eles 1,8 mm (M1, ORTHO Implant), 1,6 mm (M2, Tomas) e 1,4 mm (M3, Vector TAS), todos com comprimento de 8 mm. Por meio da microscopia eletrônica de varredura, foram calculados a profundidade da rosca, o passo da rosca (distância entre os filetes da rosca) e a relação entre os dois (TSF). Para realização do teste de tração (pull-out), os mini-implantes foram inseridos em um bloco de osso sintético. Os testes ANOVA de uma via e post-hoc de Tukey foram usados para comparar as forças de resistência à tração dos mini-implantes, considerando-se estatisticamente significativos valores de p< 0,05. Modelos de elementos finitos (MEF) foram gerados com ângulos de inserção dos mini-implantes a 90° e 60°, com força de retração em 150g. Os resultados foram analisados usando-se o software ANSYS. Resultados: Diferenças estatisticamente significativas foram encontradas entre os três mini-implantes quanto à profundidade da rosca e o passo da rosca (p< 0,001). O ORTHO Implant apresentou a maior força de resistência à tração, com significância estatística. O nível de distribuição das tensões no mini-implante e no osso circundante também foi menor para o ORTHO Implant. Resultados: Entre os diferentes tipos de mini-implantes analisados, o ORTHO Implant apresentou as características geométricas mais favoráveis e a menor tensão com o ângulo de inserção de 90°.


Subject(s)
Dental Implants , Dental Stress Analysis , Stress, Mechanical , Software , Finite Element Analysis
9.
Dental press j. orthod. (Impr.) ; 25(3): e1, May-June 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1133666

ABSTRACT

ABSTRACT Introduction: Anterior open bite is one of the most difficult malocclusions to correct in orthodontic treatment. Molar intrusion using miniscrew anchorage has been developed as a new strategy for open bite correction; however, this procedure still has an important concern about prolonged treatment duration in the patient with anteroposterior discrepancy due to the separate step-by-step movement of anterior and posterior teeth. Objective: This article illustrates a comprehensive orthodontic approach for dentoalveolar open bite correction of an adult patient, by using miniscrew. Case report: A woman 19 years and 5 months of age had chief complaints of difficulty chewing with the anterior teeth and maxillary incisor protrusion. An open bite of -2.0 mm caused by slight elongation of the maxillary molars was found. The patient was diagnosed with Angle Class II malocclusion with anterior open bite due to the vertical elongation of maxillary molars. After extraction of the maxillary first premolars, concurrent movements of molar intrusion and canine retraction were initiated with the combined use of sectional archwires, elastic chains and miniscrews. Results: At 4 months after the procedure, positive overbite was achieved subsequent to the intrusion of maxillary molars by 1.5 mm and without undesirable side effects. Class I canine relation was also achieved at the same time. The total active treatment period was 21 months. The resultant occlusion and satisfactory facial profile were maintained after 54 months of retention. Conclusion: The presented treatment shows the potential to shorten the treatment duration and to contribute to the long-term stability for open bite correction.


RESUMO Introdução: A mordida aberta anterior é um dos tipos de má oclusão mais difíceis de se corrigir no tratamento ortodôntico. A intrusão de molares usando ancoragem em mini-implantes foi desenvolvida como uma nova estratégia para a correção da mordida aberta. Entretanto, ainda há preocupações quanto à longa duração desse tratamento em pacientes com discrepâncias anteroposteriores, já que os dentes anteriores são movimentados em etapa distinta dos posteriores. Objetivo: Este artigo descreve uma abordagem ampla para a correção da mordida aberta dentoalveolar em uma paciente adulta, usando mini-implantes. Relato de caso: Uma paciente de 19 anos e 5 meses de idade procurou tratamento apresentando como queixas principais a dificuldade de mastigar com os dentes anteriores e a protrusão dos incisivos superiores. Verificou-se, ainda, mordida aberta de -2,0 mm, causada por um comprimento levemente maior dos molares superiores. A paciente foi diagnosticada com má oclusão de Classe II de Angle com mordida aberta anterior devido à dimensão vertical aumentada dos molares superiores. Após a extração dos primeiros pré-molares superiores, iniciou-se movimentos simultâneos de intrusão dos molares e retração dos caninos, com o uso combinado de arcos seccionados, elásticos em cadeia e mini-implantes. Resultados: Após quatro meses em tratamento, alcançou-se uma sobremordida positiva, devido à intrusão de 1,5 mm dos molares superiores, sem qualquer efeito colateral indesejável. Ao mesmo tempo, também alcançou-se relação de Classe I nos caninos. O tempo total de tratamento ativo foi de 21 meses. A oclusão e o perfil facial satisfatório alcançados ao fim do tratamento mantiveram-se após 54 meses em contenção. Conclusão: A abordagem aqui apresentada tem o potencial de encurtar a duração do tratamento e contribuir para a estabilidade em longo prazo da correção da mordida aberta.


Subject(s)
Humans , Female , Adult , Open Bite , Orthodontic Anchorage Procedures , Malocclusion, Angle Class II , Tooth Movement Techniques , Bone Screws , Cephalometry , Molar
10.
Braz. dent. sci ; 23(4): 1-7, 2020. ilus
Article in English | BBO, LILACS | ID: biblio-1122339

ABSTRACT

The objective of this paper is to report a clinical case of a patient who after installing an orthodontic mini-implant returned to the dental office seven days later with a severe hemorrhage where it was inserted. Because of the severe character of the hemorrhage, the mini-implant was removed, local compression was performed, medication to control bleeding was given and some lab tests were requested. The patient returned in 24 hours with diagnosis of dengue hemorrhagic fever (DHF). The patient was referred to the specialized hematology service where the diagnosis was confirmed. Past the critical period, a new mini-implant was inserted to continue the orthodontic treatment. It can be concluded from this account that despite the mini-implants being devices of simple installation and easy removal, it is important that the patient's systemic conditions are optimal for their overall effectiveness (AU)


The objective of this paper is to report a clinical case of a patient who after installing an orthodontic mini-implant returned to the dental office seven days later with a severe hemorrhage where it was inserted. Because of the severe character of the hemorrhage, the mini-implant was removed, local compression was performed, medication to control bleeding was given and some lab tests were requested. The patient returned in 24 hours with diagnosis of dengue hemorrhagic fever (DHF). The patient was referred to the specialized hematology service where the diagnosis was confirmed. Past the critical period, a new mini-implant was inserted to continue the orthodontic treatment. It can be concluded from this account that despite the mini-implants being devices of simple installation and easy removal, it is important that the patient's systemic conditions are optimal for their overall effectiveness (AU)


Subject(s)
Humans , Adult , Dengue , Orthodontic Anchorage Procedures , Hemorrhage
11.
Braz. dent. sci ; 23(3): 1-9, 2020. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1117433

ABSTRACT

A 22 year old male patient reported to the hospital with a chief complaint of forwardly placed teeth. On examination patient had Angle's Class I malocclusion and proclination of the anterior teeth. There were signs of frictional keratosis on the buccal mucosa. Treatment plan was to extract the third molars alone and distalize the entire maxillary arch with palatal mini-implants. 0.022 MBT brackets were bonded on the buccal aspect. 0.019" x 0.025" stainless steel wire was placed sequentially. Mini-implants were placed on the posterior alveolus on the palatal surface of maxilla. Retractive force was applied from an attachment bonded on the palatal aspect of the maxillary canine. Patient was reviewed periodically. Comparison of pre-treatment and post-treatment results revealed that the entire maxillary arch intruded and translated distally with a counter-clockwise rotation of the mandible with reduction in LAFH. There was a mild reduction in inter-canine with marginal expansion in the premolar and molar region. An improvement in facial profile was noted with no sign of root resorption. Thus, the posterior alveolus may be considered as a new and appropriate site for placement of mini-implant to bring about distal movement of the entire maxillary dentition (AU)


Um Paciente do sexo masculino, 22 anos, foi encaminhado ao hospital com queixa principal de dentes posicionados para a frente. Ao exame clínico o paciente apresentava má oclusão de Classe I de Angle e inclinação vestibular dos dentes anteriores. Havia sinais de queratose friccional na mucosa bucal. O plano de tratamento foi extrair os terceiros molares e distalizar todo o arco maxilar com mini-implantes por palatino. Bráquetes MBT 0,022 foram colados por vestibular. Fio de aço inoxidável 0,019 "x 0,025" foi colocado seqüencialmente. Mini-implantes foram instalados na região alveolar posterior da superfície palatina da maxila. A força de retração foi aplicada a partir de acessórios colados nas faces palatinas dos caninos superiores. O paciente foi reavaliado periodicamente. Os resultados da comparação pré-tratamento e pós-tratamento revelaram que todo o arco maxilar intruiu e transladou distalmente com rotação da mandíbula no sentido anti-horário com redução da AFAI. Houve uma ligeira redução na distância intercanina com expansão marginal nas regiões de pré-molar e molar. Foi percebida melhora no perfil facial sem sinal de reabsorção radicular. Assim, a região alveolar posterior pode ser considerada como um novo e apropriado local para instalação de mini-implante para promover movimento distal de toda a dentição maxilar. (AU)


Subject(s)
Humans , Male , Adult , Palate , Bone Screws , Orthodontic Anchorage Procedures
12.
Dental press j. orthod. (Impr.) ; 24(5): 69-78, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1039671

ABSTRACT

ABSTRACT Anterior open bite (AOB) is characterized by the lack of overlap or contact between maxillary and mandibular incisors, while the posterior teeth are in occlusion. Correction of this malocclusion is challenging due to difficulties in determining and addressing the etiologic factors, and the high relapse rate. A multidisciplinary approach may be necessary, with participation of Orthodontics, Surgery and Speech Therapy, to achieve adequate esthetic and functional results for long term stability. The present paper discusses the treatment options for AOB, their advantages and implications.


RESUMO A mordida aberta anterior (MAA) é caracterizada pela falta de cobertura ou contato entre os incisivos superiores e inferiores, enquanto os dentes posteriores estão em oclusão. A correção dessa má oclusão é considerada desafiadora, devido à dificuldade em se determinar e lidar com os fatores etiológicos e à alta taxa de recidiva. Uma abordagem multidisciplinar pode ser necessária, envolvendo a participação da Ortodontia, Cirurgia e Fonoaudiologia, a fim de que adequados resultados estéticos e funcionais sejam alcançados e se obtenha estabilidade em longo prazo. No presente artigo, o objetivo foi discutir as modalidades de tratamento da MAA, suas vantagens e implicações.


Subject(s)
Humans , Adult , Open Bite , Malocclusion , Orthodontics, Corrective , Cephalometry , Esthetics, Dental , Incisor , Maxilla
13.
Dental press j. orthod. (Impr.) ; 24(3): 71-78, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011972

ABSTRACT

ABSTRACT Objective: The objective of the present study was to perform a histological evaluation of a titanium mini-implant for orthodontic anchorage. Shear strength and fracture patterns that occurred immediately, 30 and 60 days after insertion with or without N-2-butyl-cyanoacrylate adhesive were evaluated. Methods: Ninety-six mini-implants (Arrow, Peclab, Brazil) were placed in the tibia of 9 male rabbits, with or without an adhesive (Vetbond™, 3M, USA). Histological evaluation was done by optical light microscope. Shear strength testing was performed, followed by fracture analysis with visual inspection. Results: Close contact between the newly formed bone and the device was evidenced in the group without adhesive, whereas gaps in the group with adhesive were found. Tukey test showed similar values in both groups at the immediate time point (20.70 N without adhesive and 24.69 N with adhesive), and higher values for the non-adhesive group, after 30 and 60 days (43.98 N and 78.55 N, respectively). The values for the adhesive group were similar for the immediate time point (24.69 N), 30 days (18.23 N) and 60 days (31.98 N). The fractures were adhesive for both groups at the immediate time point. The fractures were cohesive in bone for the non-adhesive group after 30 and 60 days. Conclusions: The mini-implants showed close bone contact and required higher shear strength for removal at 30 and 60 days for the non-adhesive group. Further studies are needed to assess the proper way to remove the orthodontic anchorage without cohesive fractures in bone.


RESUMO Objetivos: este estudo teve como objetivo realizar uma avaliação histológica de um mini-implante para ancoragem em Ortodontia. Avaliou-se, também, a carga de cisalhamento e o padrão de fratura imediatamente e após 30 e 60 dias da sua inserção, com ou sem o uso do adesivo N-butil-2-cianoacrilato. Métodos: noventa e seis mini-implantes (Arrow, Peclab, Brasil) foram instalados na tíbia de nove coelhos machos, com ou sem adesivo (Vetbond™, 3M, EUA). A avaliação histológica foi realizada com uso de microscópico de luz óptica. Realizou-se o teste de resistência ao cisalhamento, seguido pela análise da fratura, por meio de inspeção visual. Resultados: um contato íntimo entre o novo osso formado e o dispositivo foi evidenciado no grupo sem adesivo, enquanto espaços foram encontrados no grupo com adesivo. O teste de Tukey mostrou valores semelhantes em ambos os grupos no tempo imediato (20,70 N sem adesivo e 24,69 N com adesivo), e valores maiores para o grupo sem adesivo após 30 e 60 dias (43,98 N e 78,55 N, respectivamente). Os valores para o grupo com adesivo foram semelhantes para os tempos imediato (24,69 N), 30 dias (18,23 N) e 60 dias (31,98 N). As fraturas foram adesivas para ambos os grupos, no tempo imediato. As fraturas foram coesivas no osso para os grupos sem adesivo, após 30 e 60 dias. Conclusões: os mini-implantes mostraram um contato íntimo com o osso e requereram alta carga de cisalhamento para sua remoção após 30 e 60 dias nos grupos sem adesivo. Estudos adicionais são necessários para avaliar um método para remoção do dispositivo ortodôntico sem fratura coesiva no osso.


Subject(s)
Animals , Male , Rabbits , Dental Implants , Orthodontic Anchorage Procedures , Stress, Mechanical , Titanium , Materials Testing , Brazil , Cyanoacrylates , Dental Cements
14.
Rev. odontol. UNESP (Online) ; 47(6): 376-382, nov.-dez. 2018. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-985726

ABSTRACT

Introdução: Mini-implantes ortodônticos são dispositivos de ancoragem confeccionados à base de titânio, possuindo uma camada de óxido de titânio, que desempenha função importante na resistência à corrosão. Objetivo: O objetivo deste estudo foi avaliar a resistência à corrosão e a microestrutura superficial de mini-implantes novos, utilizados que foram perdidos precocemente e os que obtiveram sucesso de estabilidade, analisando se o processo de corrosão influencia a falha ou a perda de estabilidade, a fim de se comparar com as principais causas de sucesso e insucesso clínico. Material e método: A amostra foi composta por 3 grupos de 7 mini-implantes divididos da seguinte maneira: Grupo C: mini-implantes na sua forma original, como são recebidos do fabricante (controle); Grupo PE: mini-implantes utilizados em pacientes e que apresentaram perda de estabilidade precoce em até 2 meses (média de 33,5 dias); Grupo E: mini-implantes utilizados em pacientes com sucesso de estabilidade (média de 230 dias). A análise visual da superfície da rosca dos mini-implantes foi feita através de microscópio eletrônico de varredura e todos foram submetidos a ensaio de polarização cíclica potenciodinâmica em potenciostato. Resultado: A microestrutura superficial não foi significativamente alterada pela permanência e perda precoce de estabilidade em seus sítios ósseos. Conclusão: Os dados sugeriram que a corrosão não foi fator associado à falha do dispositivo ou perda de sua estabilidade, sendo outros fatores, como o tipo do mini-implante, o seu comprimento e o local de implantação, considerados mais preponderantes com influência no seu insucesso.


Introduction: Orthodontic miniscrew are titanium-based anchoring devices, having a layer of titanium oxide, which plays an important role in corrosion resistance. Objective: The objective of this study was to evaluate the corrosion resistance and surface microstructure of new miniscrew, those who were used and lost early and those who had achieved stability success, analyzing if the corrosion process influences the failure or the loss of stability of it, in order to compare with the main causes of success and clinical unsuccess. Materials and method: The sample consisted of 3 groups of 7 miniscrews divided as follows: Group C: miniscrews in their original form, as they are received from the manufacturer (control); Group PE: miniscrews used in patients with early loss of stability in up to 2 months (mean of 33.5 days); Group E: miniscrews used in patients with stability success (mean of 230 days). The visual analysis of the screw surface of the miniscrews was done by scanning electron microscope and all were submitted to a cyclic potentiodynamic polarization in potentiostat. Result: The surface microstructure was not significantly altered by the permanence and early loss of stability in its bone sites. Conclusion: The data suggests that corrosion was not a factor associated with device failure or loss of stability, being other factors such as the type of miniscrews, its length and the site of implantation considered to be the most preponderant with influence in its failure.


Subject(s)
Orthodontics , Titanium , Microscopy, Electron, Scanning , Dental Etching , Orthodontic Anchorage Procedures
15.
Dental press j. orthod. (Impr.) ; 23(5): 39.e1-39.e13, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-975019

ABSTRACT

Abstract Introduction: The selection of appropriate sites for miniscrew insertion is critical for clinical success. Objectives: The aim of the present study was to evaluate how interradicular spaces measured on panoramic radiograph compare with Cone-Beam Computed Tomography (CBCT), and how crowding can influence the presence of available space for miniscrew insertion, in order to define a new "safe zones" map. Methods: A total of 80 pre-treatment panoramic radiographs and 80 CBCT scans with corresponding digital models were selected from the archives of the department of Dentistry, Aarhus University. Crowding was measured on digital models, while interradicular spaces mesial to the second molars were measured on panoramic radiographs and CBCTs. For panoramic radiographs, a magnification factor was calculated using tooth widths measured on digital models. Statistical analyses were performed to investigate the correlation between the amount of crowding and the available interradicular space. Visual maps showing the amount of interradicular spaces measured were drawn. Results: The most convenient interradicular spaces are those between the second molar and the first premolar in the mandible, and between the central incisors in the maxilla. However, some spaces were revealed to be influenced by crowding. Conclusions: Calibration of panoramic radiographs is of utmost importance. Generally, panoramic radiographs underestimate the available space. Preliminary assessment of miniscrew insertion feasibility and the related selection of required radiographs can be facilitated using the new "safe zone" maps presented in this article.


Resumo Introdução: a seleção de locais apropriados para a inserção de mini-implantes é crítica para o sucesso clínico. Objetivo: os objetivos do presente estudo foram avaliar as medições de espaços inter-radiculares feitas em radiografias panorâmicas e compará-las com as medições feitas com tomografia computadorizada de feixe cônico (TCFC), além de avaliar como o apinhamento pode influenciar na disponibilidade de espaços para inserção dos mini-implantes, no intuito de definir um novo mapa de "áreas seguras". Métodos: foram selecionadas, nos arquivos do departamento de Ortodontia da Aarhus University, 80 radiografias panorâmicas pré-tratamento e 80 imagens de TCFC com os modelos digitais correspondentes. O apinhamento foi medido nos modelos digitais, enquanto os espaços inter-radiculares mesiais aos segundos molares foram medidos nas radiografias panorâmicas e na TCFC. O fator de magnificação das radiografias panorâmicas foi calculado utilizando-se as larguras dentárias medidas nos modelos digitais. Análises estatísticas foram realizadas para investigar a correlação entre a quantidade de apinhamento e o espaço inter-radicular disponível. Foram desenhados mapas visuais mostrando a quantidade dos espaços inter-radiculares medidos. Resultados: os espaços inter-radiculares mais adequados são aqueles entre o segundo molar e o primeiro pré-molar inferior, e entre os incisivos centrais superiores. Porém, verificou-se que alguns espaços são influenciados pelo apinhamento. Conclusões: A calibração das radiografias panorâmicas é de suma importância, pois, geralmente, as radiografias panorâmicas subestimam o espaço disponível. A avaliação preliminar da viabilidade de inserção dos mini-implantes e a seleção das radiografias necessárias para isso podem ser facilitadas utilizando-se os novos mapas de "áreas seguras" aqui apresentados.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Bone Screws , Dental Arch/diagnostic imaging , Orthodontic Anchorage Procedures/methods , Molar/diagnostic imaging , Calibration , Radiography, Panoramic , Retrospective Studies , Dental Arch/anatomy & histology , Dental Implantation/methods , Cone-Beam Computed Tomography , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Molar/anatomy & histology
16.
Dental press j. orthod. (Impr.) ; 23(1): 108-117, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-891116

ABSTRACT

ABSTRACT Introduction: The T-loop as designed by Burstone is a space closure spring used in the rational application of orthodontic biomechanics. Despite the diversity of studies, there is still no consensus on the optimal parametric characteristics for its conformation. Objective: This study aimed at reviewing the literature on the force systems released by different conformations of the T-loop, according to the type of anchorage and the main characteristics and factors that influence them. Results: Comparing the studies, the need for standardization was perceived in the methodology to shape the loops, regarding the variables that influence the force system. Most of the experimental studies with this loop do not report the vertical movement, nor the steps and angles that occur in the brackets. Clinical studies have obtained more variable results in relation to vertical acting forces, considering the influence of chewing. Conclusion: There is great potential for future studies with this type of loop, especially using nickel-titanium alloys, in order to achieve a pure translational movement without friction, with optimal and constant levels of force.


RESUMO Introdução: a alça T preconizada por Burstone é um instrumento de fechamento de espaços utilizado na aplicação racional da biomecânica ortodôntica, dentro da técnica do arco segmentado. Apesar da diversidade de estudos, ainda não há consenso quanto às características paramétricas ótimas para a sua conformação. Objetivo: esse estudo teve como objetivo revisar a literatura sobre os sistemas de forças liberados por diferentes conformações da alça T, de acordo com o tipo de ancoragem necessária, salientando suas principais características e os fatores que as influenciam. Resultados: comparando-se os estudos, foi perceptível a necessidade de padronização da metodologia usada para conformar as alças, levando em consideração as variáveis que exercem influência no sistema de forças, de forma a se obter sistemas mais acurados, permitindo a realização de testes mais precisos e uma comparação mais eficaz dos estudos. A maioria dos estudos experimentais com esse tipo de alça não relata a movimentação vertical, nem os degraus e ângulos que ocorrem nos braquetes. Estudos clínicos obtiveram resultados menos rígidos em relação às forças verticais atuantes, levando em consideração a influência da mastigação. Conclusões: há grande potencial para futuros estudos com esse tipo de alça, especialmente utilizando ligas de níquel-titânio, para que se chegue cada vez mais perto de um movimento de translação puro e sem atrito, com níveis de força ótimos e constantes.


Subject(s)
Humans , Orthodontic Wires , Orthodontic Appliance Design , Orthodontic Space Closure/instrumentation
17.
Dental press j. orthod. (Impr.) ; 22(5): 47-55, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-891100

ABSTRACT

ABSTRACT Objective: The aim of the present study was to clarify the biomechanics of en-masse retraction of the upper anterior teeth and attempt to quantify the different forces and moments generated using mini-implants and to calculate the amount of applied force optimal for en-masse intrusion and retraction using mini-implants. Methods: The optimum force required for en-masse intrusion and retraction can be calculated by using simple mathematical formulae. Depending on the position of the mini-implant and the relationship of the attachment to the center of resistance of the anterior segment, different clinical outcomes are encountered. Using certain mathematical formulae, accurate measurements of the magnitude of force and moment generated on the teeth can be calculated for each clinical outcome. Results: Optimum force for en-masse intrusion and retraction of maxillary anterior teeth is 212 grams per side. Force applied at an angle of 5o to 16o from the occlusal plane produce intrusive and retraction force components that are within the physiologic limit. Conclusion: Different clinical outcomes are encountered depending on the position of the mini-implant and the length of the attachment. It is possible to calculate the forces and moments generated for any given magnitude of applied force. The orthodontist can apply the basic biomechanical principles mentioned in this study to calculate the forces and moments for different hypothetical clinical scenarios.


RESUMO Objetivo: o objetivo do presente estudo foi explicar o funcionamento da biomecânica de retração em massa dos dentes anterossuperiores e tentar quantificar as diferentes forças e momentos gerados ao se usar mini-implantes, além de calcular a quantidade ideal de força a ser aplicada para se obter a intrusão/retração em massa ancorada em mini-implantes. Métodos: a força ideal necessária para se realizar a intrusão/retração em massa pode ser calculada por meio de fórmulas matemáticas simples. Dependendo da posição do mini-implante e da posição do acessório, a ele conectado, com relação ao centro de resistência do segmento anterior, obtêm-se desfechos clínicos diferentes. Aplicando certas fórmulas matemáticas, pode-se calcular com precisão a magnitude da força e do momento gerado nos dentes, para cada desfecho clínico. Resultados: a força ideal para se obter a intrusão/retração em massa dos dentes anterossuperiores é de 212 gramas por lado. A força aplicada em um ângulo de 5° a 16° em relação ao plano oclusal produz componentes de força de intrusão/retração que se encontram dentro dos limites fisiológicos. Conclusão: podem ser encontrados diferentes desfechos clínicos dependendo da posição do mini-implante e do comprimento do acessório. É possível calcular as forças e os momentos gerados para qualquer magnitude de força aplicada. Assim, o ortodontista clínico pode aplicar os princípios biomecânicos básicos apresentados nesse estudo para calcular as forças e os momentos em diferentes cenários clínicos hipotéticos.


Subject(s)
Humans , Tooth Movement Techniques/instrumentation , Dental Stress Analysis/methods , Orthodontic Anchorage Procedures/instrumentation , Biomechanical Phenomena , Orthodontic Space Closure/instrumentation , Maxilla , Models, Theoretical
18.
Dental press j. orthod. (Impr.) ; 22(3): 97-108, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-891072

ABSTRACT

ABSTRACT Introduction: Etiology of dental crowding may be related to arch constriction in diverse dimensions, and an appropriate manipulation of arch perimeter by intervening in basal bone discrepancies cases, may be a key for crowding relief, especially when incisors movement is limited due to underlying pathology, periodontal issues or restrictions related to soft tissue profile. Objectives: This case report illustrates a 24-year old woman, with maxillary transverse deficiency, upper and lower arches crowding, Class II, division 1, subdivision right relationship, previous upper incisors traumatic episode and straight profile. A non-surgical and non-extraction treatment approach was feasible due to the miniscrew-assisted rapid palatal expansion technique (MARPE). Methods: The MARPE appliance consisted of a conventional Hyrax expander supported by four orthodontic miniscrews. A slow expansion protocol was adopted, with an overall of 40 days of activation and a 3-month retention period. Intrusive traction miniscrew-anchored mechanics were used for correcting the Class II subdivision relationship, managing lower arch perimeter and midline deviation before including the upper central incisors. Results: Post-treatment records show an intermolar width increase of 5 mm, bilateral Class I molar and canine relationships, upper and lower crowding resolution, coincident dental midlines and proper intercuspation. Conclusions: The MARPE is an effective treatment approach for managing arch-perimeter deficiencies related to maxillary transverse discrepancies in adult patients.


RESUMO Introdução: a etiologia do apinhamento dentário pode estar relacionada à constrição das arcadas dentárias em diversas dimensões, e a manipulação apropriada do perímetro da arcada, por meio da intervenção em casos de discrepâncias de base óssea, pode ser o fator chave para a dissolução do apinhamento, especialmente em casos onde a movimentação de incisivos é limitada em decorrência de problemas periodontais ou restrições relacionadas ao perfil facial. Objetivos: o presente relato de caso ilustra uma paciente de 24 anos de idade, com deficiência transversa de maxila, apinhamento das arcadas superior e inferior, má oclusão de Classe II, 1a divisão, subdivisão direita, incisivos superiores previamente traumatizados e perfil reto. A abordagem de tratamento não-cirúrgica e sem extrações foi viável devido à técnica de expansão rápida da maxila assistida por mini-implantes (MARPE, do inglês miniscrew-assisted rapid palatal expansion). Métodos: o dispositivo MARPE foi confeccionado a partir de um expansor Hyrax convencional apoiado em quatro mini-implantes. Foi adotado o protocolo de expansão lenta, com um período total de ativações de 40 dias e 3 meses de contenção. Uma mecânica de tração intrusiva apoiada em mini-implantes foi utilizada para a correção da relação de Classe II subdivisão direita, adequação do perímetro da arcada inferior e correção do desvio da linha média antes da inclusão dos incisivos centrais superiores. Resultados: os registros pós-tratamento demonstraram o aumento de 5,0 mm na distância intermolares, relação bilateral de Classe I de molares e caninos, resolução do apinhamento superior e inferior, linhas médias dentárias coincidentes e intercuspidação adequada. Conclusões: a técnica MARPE é uma abordagem de tratamento efetiva para a resolução da deficiência de perímetro das arcadas dentárias relacionada à discrepância maxilar transversa em pacientes adultos.


Subject(s)
Humans , Female , Young Adult , Bone Screws , Palatal Expansion Technique/instrumentation , Dental Arch/pathology , Malocclusion, Angle Class II/therapy , Biomechanical Phenomena , Radiography, Panoramic , Cephalometry , Orthodontic Appliance Design , Dental Arch/diagnostic imaging , Malocclusion, Angle Class II/diagnostic imaging
19.
Ortho Sci., Orthod. sci. pract ; 10(39): 148-155, 2017. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-868264

ABSTRACT

O caso relatado no presente artigo refere-se a uma paciente com má oclusão de Classe II de Angle que foi tratada em duas fases: a primeira consistindo na instalação de um distalizador intrabucal First Class modificado, associado a mini-implantes no palato e a segunda consistindo no aparelho fixo. A severidade da discrepância anteroposterior era moderada, com apinhamento leve em ambos os arcos, sem comprometimento esquelético significante. O aparelho promoveu distalização dos molares, bem como uma pequena perda de ancoragem nos dentes anteriores à distalização. A segunda fase com aparelho fixo visou promover o alinhamento e nivelamento dos arcos, bem como a retração anterior, auxiliada por uma ancoragem baseada em um botão de Nance associado aos mini-implantes. Ao final do tratamento foram observadas a correção da discrepância anteroposterior dos arcos, bem como uma oclusão balanceada e estética satisfatória.(AU)


The present case report refers to a patient with Angle Class II malocclusion who was treated in two phases: the first phase consisting of the installation of a modified First Class intraoral distalizer associated with mini implants on the palate, and the second phase consisting of a fixed appliance. The anteroposterior discrepancy severity was moderate, with light crowding in both arches, without significant skeletal component. The device promoted distalization of the molars, as well as a small loss of anchorage in the anterior teeth. The second phase with a fixed appliance promoted the alignment and leveling of the arches, as well as the anterior retraction, assisted by an anchorage reinforcement based on a Nance button associated to the mini implants. At the end of the treatment the anteroposterior discrepancy was corrected and a balanced and esthetic occlusion was observed.(AU)


Subject(s)
Humans , Female , Child , Malocclusion, Angle Class II , Orthodontic Anchorage Procedures , Orthodontic Appliances
20.
Ortho Sci., Orthod. sci. pract ; 10(39): 331-340, 2017. ilus, graf
Article in Portuguese | LILACS, BBO | ID: biblio-868289

ABSTRACT

O objetivo desse estudo foi comparar a eficácia entre a tomografia computadorizada de feixe cônico (padrão-ouro) e as radiografias periapical, interproximal e panorâmica digitais para avaliação do espaço inter-radicular com vistas à instalação de mini-implantes. Métodos: a amostra foi composta por 40 sítios eleitos nos espaços inter-radiculares na região posterior. Os pontos de inserção para instalação dos mini-implantes foram representados por guta-percha em moldeira de acetato que os pacientes usavam durante as radiografias e a tomografia. Através do programa Adobe Acrobat 9 Pro Extend foram feitas medidas interradiculares no sentido horizontal nos três métodos radiográficos e comparadas com as da tomografia, que foram realizadas pelo Kodak Dental Imaging Software 3D. A comparação utilizou o coeficiente de Lin. Resultados: foi observada diferença estatisticamente significante entre a tomografia computadorizada e as radiografias panorâmicas (27,8% - P > 0,05). Conclusões: a radiografia interproximal foi o método mais preciso; a radiografia panorâmica e a periapical não são recomendadas para verificação do espaço inter-radicular, pois apresentaram alteração da dimensão dessa região no sentido horizontal.(AU)


The objective of this study was to compare the assessment of interradicular space for mini-implants fitting between the cone beam computed tomography (gold standard) and periapical, interproximal and panoramic digital radiographies. Methods: The sample consisted of 40 elected interradicular sites in the posterior area of five patients. These areas were represented by gutta percha points in acetate trays that patients used when radiographies and tomographies were taken. Horizontal measures, between dental roots, in three radiographic methods were obtained by Adobe Acrobat 9 Pro Extend program and compared with the tomography obtained by Kodak Dental Imaging Software 3D. The comparison was done by Lin coefficient correlation. Results: there was not stastistically difference between tomoghaphy and interproximal radiography (8,4% - p < 0,05). Conclusions: the interproximal radiography was the most accurate radiographic method; the panoramic and periapical radiographies are not recommended for interradicular space verification, because they present horizontal dimension alterations in this region. (AU)


Subject(s)
Diagnostic Imaging , Orthodontic Anchorage Procedures , Radiography, Dental , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL